LMI 6000 Auto Cut

Melt flow indexer for MFR and MVR measurement with automatic sample cutting

Manufacturer
Dynisco
Order code
LMI6000-2-N-N-N-N-C-N-N

The LMI 6000 is a next-generation melt flow indexer (an instrument for measuring the melt flow index) from Dynisco. With illustrated instructions directly in the software, semi-automatic test procedures and several data acquisition options, you can verify material properties more easily than ever before – before the material enters production.

The Auto Cut version is equipped with automatic sample cutting at preset time intervals for Methods A and A/B – sampling is consistent and independent of the operator.

Benefits

  • Larger 10.2″ touchscreen – left- or right-hand mounting and adjustable height
  • One-touch test start and illustrated step-by-step instructions in the software
  • Methods A, A/B, B, C and D to ASTM D1238 and ISO 1133 (Method D with automatic weight lift)
  • Intrinsic viscosity (IV) determination using a modified Method B
  • Temperature control to ±0.1 °C from ambient to 400 °C
  • Safe shutdown via a dedicated button – data is always saved first
Applications:
  • Incoming quality control of polymers
  • Recyclate processing
  • Plastics production and compounding
  • Materials research and development
  • Testing laboratories

We will send you the price, delivery time and any available variants in our quotation.

Go to inquiry

Need help choosing? Call us on +420 571 647 228 or write to info@azurr-tech.cz.

Technical data

Digital encoderNot equipped
Automatic cutting systemIncluded
Standard temperature controlStandard ISO 1133 / ASTM1238
Power supply220-240 Vac 50/60Hz
Temperature rangeambient to 400 °C
Temperature stability±0,1 ℃
Timer accuracy0.001 S
Weights0.325 to 31.6 kg
Display10.2″ capacitive touchscreen
Interface4× USB, PC, balance and printer connection
Dimensions (H × W × D)68.3 × 44.7 × 52.8 cm
Power consumptionmax. 500 W, typically 100 W at steady-state temperature

Description

MFR, MVR and intrinsic viscosity measurement

Melt mass-flow rate (MFR), melt volume-flow rate (MVR) and intrinsic viscosity (IV) are key parameters for how a material behaves during processing and for the properties of the finished product. They cannot be judged by eye, and the actual values may differ from those given in the material data sheet.

The LMI 6000 performs tests to Methods A, A/B, B, C and D (Method D is only available with the automatic weight lift). Intrinsic viscosity (IV) can also be determined using a modified Method B procedure.

Whether you are a manufacturer, recycler, researcher or quality control professional, the LMI 6000 lets you verify that a material meets the required specification and track differences between individual polymer batches.

Enhanced performance

The LMI 6000 represents a new generation of instruments offering greater user comfort, easier operation and improved performance. Features include a larger, repositionable touchscreen, an upgraded hardware architecture and software automation that starts the test procedure at the press of a single button.

Advanced software

Tests can be performed with manual weight loading or with the optional electromechanical automatic weight lift, which allows simultaneous testing on several instruments. Once the barrel has been charged with a small amount of material, the instrument carries out most of the measurement without the operator being present.

Automatic loading and removal of the weights improves operator safety, as operators no longer have to handle heavy weights repeatedly, and also improves measurement accuracy and repeatability.

Ergonomics and operation

The new hardware architecture provides faster response and smoother operation of the user interface. A dedicated power button shuts the instrument down safely – all measured data is saved first and only then is the power disconnected.

The larger touchscreen on the side of the instrument can be mounted on the left or right and adjusted in height to suit the operator. The side position also reduces the risk of damage to the display should a weight be dropped.

Options

Digital encoder – measures piston displacement with very high accuracy in tests to Methods A/B and B.

Automatic sample cutting – cuts samples at preset intervals in tests to Methods A and A/B and can also cut the sample at the end of the preheat time, regardless of the test method. Sampling is therefore more consistent and repeatable than with manual cutting.

Auto-Lift automatic weight lift – an electromechanical system for loading and removing weights that requires no compressed air supply, only electrical power. It is available for a single weight or for a multiple-weight set and offers a higher level of automation, better ergonomics and improved operator safety.

Standards and test methods

  • ASTM D1238
  • ASTM D3364
  • ISO 1133-1
  • ISO 1133-2
  • BS 2782
  • DIN 53735
  • JIS K 7210

Optional equipment

  • Digital encoder for accurate measurement of piston displacement (Methods A/B and B)
  • Automatic sample cutting at preset intervals (Methods A and A/B)
  • Auto-Lift automatic weight lift for one or more weights – no compressed air required

More products in this category

Melt flow indexers

LMI 6000 Basic Model

Next-generation melt flow indexer for MFR, MVR and IV measurement Order code: LMI6000-2-N-N-N-N-N-N-N · Dynisco
Melt flow indexers

LMI 6000 Digital Encoder AutoCut

Melt flow indexer with digital encoder and automatic sample cutting Order code: LMI6000-2-N-E-N-N-C-N-N · Dynisco
Melt flow indexers

LMI 6000 Digital Encoder

Melt flow indexer with digital encoder for accurate MVR measurement Order code: LMI6000-2-N-E-N-N-N-N-N · Dynisco
Melt flow indexers

LMI 6000 Digital Encoder 1133-2

Melt flow indexer with digital encoder for testing to ISO 1133-2 Order code: LMI6000-2-N-E-N-N-N-I-N · Dynisco
Melt flow indexers

LMI5500, LMFI55-2NNNNCN

Order code: LMFI55-2NNNNCN · Dynisco
  • Digital encoder: Not equipped
  • Standard temperature control: Standard ISO 1133 / ASTM1238
  • Automatic cutting system: Included