SIKORA LASER Series 2000

Non-contact laser measurement of diameter and ovality of extruded products

Manufacturer
SIKORA

SIKORA LASER Series 2000 is a series of laser measuring heads for non-contact online diameter measurement in two or three axes and for measuring the width and height of flat products. It covers product diameters of 0.05–300 mm.

Benefits

  • Non-contact, non-destructive laser diameter measurement
  • CCD sensing technology combined with pulse-driven laser light sources
  • Extremely short exposure time of 0.2 µs
  • Diameter calculated by diffraction analysis directly from the shadow image
  • Stand-alone data processing
  • No moving parts – no maintenance or calibration required
  • Two-axis measuring heads (XY) for measuring diameter in two planes
  • Three-axis measuring heads (T) for measuring ovality, including the orientation of the oval
  • Measurement of width and height of flat products twisted by up to ±15° (F/R)
  • RS485 and RS232 interfaces, optionally analogue interface, Profibus-DP, Profinet IO and other industrial fieldbuses
Applications:
  • Cables and wires
  • Pipes and hoses
  • Flat two-, three- and multi-core cables
  • Flat hose profiles
  • Extruded products of round cross-section

We supply the equipment configured for your application. In your inquiry, please state the material processed, the required throughput and the line parameters – we will prepare a tailored quotation.

Go to inquiry

Need help choosing? Call us on +420 571 647 228 or write to info@azurr-tech.cz.

Technical data

Measuring principleNon-contact, CCD technology with pulse-driven laser light sources, diffraction analysis
Product diameter – XY0.05–300 mm (LASER 2005 XY to LASER 2300 XY)
Product diameter – T0.2–100 mm (LASER 2010 T to LASER 2100 T)
Measuring range – F/Rround products 0.2–50 mm; flat products: width 0.5–50 mm, thickness 0.25–25 mm
Accuracy±0.5 µm to ±20 µm depending on model; F/R profiles ±5.0 µm / ±10 µm
Repeatability±0.1 µm to ±4.0 µm depending on model
Exposure time0.2 µs
Measuring frequency500/s per axis; LASER 2050 T 1,000/s per axis; LASER 2005 XY 1,200/s per axis
Power supply100–240 V AC ±10 %, 50/60 Hz, 30 VA
InterfaceRS485, RS232; optionally analogue interface, Profibus-DP or Profinet IO, or CANopen, EtherNet/IP, DeviceNet, OPC UA (in conjunction with ECOCONTROL)
Dimensions (W × H × D)140 × 140 × 63 mm (LASER 2005 XY) to 920 × 920 × 133 mm (LASER 2300 XY)

Description

The SIKORA LASER Series 2000 uses a non-contact, non-destructive laser principle for diameter measurement and serves to ensure quality and to optimize and stabilize the production process. CCD sensing technology combined with pulse-driven laser light sources allows an extremely short exposure time of 0.2 µs. The measuring heads process data independently and work without moving parts, so they require neither maintenance nor calibration.

The two-axis LASER Series 2000 XY measuring heads measure the diameter in two planes; the diameter is calculated by diffraction analysis directly from the shadow image. Seven models, from LASER 2005 XY to LASER 2300 XY, cover product diameters of 0.05–300 mm.

The three-axis LASER Series 2000 T measuring heads measure the diameter including the minimum and maximum values and are aimed primarily at measuring the ovality of extruded products. An oval is defined by five tangents; with three measuring axes and six tangents, not only the minimum and maximum values but also the orientation of the oval are therefore determined.

The LASER Series 2000 F/R version is designed for online measurement of flat two-, three- and multi-core cables, round conductors and flat hose profiles. It measures the width and height of flat products, even when they are twisted by up to ±15°, or the diameter of round products. The measured values can be shown on the DISPLAY 2000 or on ECOCONTROL series processor systems.

Optional equipment

  • LASER Series 2000 XY – two-axis measuring heads LASER 2005 XY, 2010 XY, 2030 XY, 2050 XY, 2100 XY, 2200 XY and 2300 XY
  • LASER Series 2000 T – three-axis measuring heads LASER 2010 T, 2025 T, 2050 T and 2100 T
  • LASER Series 2000 F/R – LASER 2030 F/R and LASER 2050 F/R measuring heads for flat and round products
  • Analogue interface, Profibus-DP or Profinet IO
  • CANopen, EtherNet/IP, DeviceNet, OPC UA industrial fieldbuses (in conjunction with ECOCONTROL)
  • DISPLAY 2000 display unit or ECOCONTROL series processor systems

More products in this category

Diameter and ovality measurement

SIKORA CENTERVIEW 8000

Non-contact measurement of eccentricity, wall thickness, diameter and ovality of cables
Diameter and ovality measurement

SIKORA CENTERVIEW PRO

Measurement of cable eccentricity and diameter in 4 axes with FFT analysis
Diameter and ovality measurement

SIKORA FIBER Series 6000

Measurement of diameter, temperature and tension of optical fibres and lump detection in the draw tower
Diameter and ovality measurement

SIKORA LASER PRO

Laser measuring heads for high-precision online diameter measurement in extrusion