SIKORA SPARK (HF, AC, DC)

Spark testers for detecting faults and bare spots in the insulation of wires and cables

Manufacturer
SIKORA

SIKORA SPARK spark testers reliably detect point defects and bare spots in the insulation of wires and cables. The series includes high-frequency (HF), alternating-current (AC) and direct-current (DC) testers for diameters of up to 200 mm with adjustable test voltage.

Benefits

  • Reliable detection of point defects and bare spots in the insulation
  • Adjustable test voltage
  • Compliance with IEC and UL test standards and with safety regulations according to IEC 60479-1
  • SPARK AC alternating-current testers for diameters of 1–200 mm with synchronization to the mains frequency of 50–60 Hz
  • Easy installation in new and existing lines
  • SPARK 30 HF and SPARK 20 DC distinguish between pinholes and bare spots
  • Integrated display showing the test voltage and number of breakdowns, and control panel (SPARK 30 HF, SPARK 20 DC)
  • Stand-alone solution for lines without a line computer
  • Optional three-stage self-test and calibration for SPARK 30 HF
  • Ethernet/UDP interface, analogue input and output of the test voltage, potential-free contacts
Applications:
  • Cables and wires
  • Automotive cables
  • Installation cables

We supply the equipment configured for your application. In your inquiry, please state the material processed, the required throughput and the line parameters – we will prepare a tailored quotation.

Go to inquiry

Need help choosing? Call us on +420 571 647 228 or write to info@azurr-tech.cz.

Technical data

Product diameter – AC1.0–60 mm (SPARK 60 AC), 1.0–100 mm (SPARK 100 AC), 1.0–140 mm (SPARK 140 AC), 1.0–200 mm (SPARK 200 AC)
Product diameter – DC1.0–20 mm (SPARK 20 DC)
Product diameter – HF / ULup to 30 mm (SPARK 30 HF, SPARK 2030 UL)
Test voltage – AC1.6–25 kV (optionally 30/35 kV)
Test voltage – DC1,0–20 kV DC
Test voltage – HF / UL1,0–15 kV (RMS)
Integrated displaySPARK 20 DC, SPARK 30 HF
Integrated self-testSPARK 30 HF (optional)
InterfaceRS485, RS232, analogue input and output of the test voltage, potential-free contacts, Ethernet/UDP
Optional interfacesSPARK HF/DC/AC: Profibus-DP, Profinet, EtherNet/IP, CANopen, DeviceNet, EtherCAT; SPARK UL: Profibus-DP, Profinet
Power supply100–240 V AC ±10 %, 50/60 Hz

Description

SIKORA SPARK spark testers reliably detect point defects and bare spots in the insulation of wires and cables, thus ensuring that only defect-free cables are delivered. The test voltage is adjustable. The instruments comply with the most important test standards (IEC, UL) and safety regulations according to IEC 60479-1.

The SPARK AC alternating-current spark testers cover a diameter range of 1–200 mm. They are easy to install in new and existing lines, synchronize with the frequency of the mains voltage and operate at 50–60 Hz. They can optionally be combined with the REMOTE 6000 display and operating unit, which contains a display and keypad for setting the test voltage and a fault counter, and optionally allows length-related logging of detected breakdowns.

SPARK 30 HF is a high-frequency, high-voltage spark tester for reliable detection of insulation faults, e.g. on automotive and installation cables with a diameter of 0.5–30 mm. The SPARK 20 DC direct-current spark tester detects insulation faults on conductors with a diameter of 1.0–20 mm. Both instruments reliably distinguish between pinholes and bare spots, have an integrated display showing the selected test voltage and number of breakdowns and a control panel for setting the voltage; for lines without a line computer they are suitable as stand-alone solutions. Where an integrated display and a self-test and calibration system are not needed, the SPARK 2030 UL model is an alternative to the SPARK 30 HF.

An integrated three-stage self-test and calibration system is optionally available for the SPARK 30 HF: a high-voltage test (tolerance 5 %), a test of the maximum short-circuit current on accidental contact with the test electrode (max. 10 mA according to EN 61010-1:2010) and a functional sensitivity test in which 20 artificial faults (breakdowns) are triggered, detected and reported.

Standards and test methods

  • IEC
  • UL
  • IEC 60479-1
  • EN 61010-1:2010

Optional equipment

  • SPARK 60 AC, SPARK 100 AC, SPARK 140 AC and SPARK 200 AC – AC spark testers
  • SPARK 20 DC – DC spark tester
  • SPARK 30 HF – high-frequency spark tester
  • SPARK 2030 UL – alternative to SPARK 30 HF without the integrated display and self-test and calibration system
  • Test voltage of 30/35 kV for SPARK AC models
  • Integrated three-stage self-test and calibration for SPARK 30 HF
  • REMOTE 6000 display and operating unit with fault counter and length-related breakdown logging
  • Profibus-DP, Profinet, EtherNet/IP, CANopen, DeviceNet, EtherCAT industrial fieldbuses (SPARK HF/DC/AC); Profibus-DP, Profinet (SPARK UL)

More products in this category

Defect detection and spark testers

SIKORA LUMP 2000

Detection of lumps and neckdowns on the surface of cables and wires at any line speed
Defect detection and spark testers

SIKORA CAPACITANCE 2000

Cable capacitance measurement with FFT analysis, SRL prediction and bare spot detection