SIKORA X-RAY 8000 ADVANCED/NXT
X-ray measurement of wall thickness and eccentricity of cables on CV lines
SIKORA X-RAY 8000 ADVANCED/NXT is an X-ray measuring system for CV (continuous vulcanization) lines that measures the diameter, wall thickness and eccentricity of medium-voltage, high-voltage and extra-high-voltage cables. It enables fast centring of the crosshead and process control.
Benefits
- Eight-point display of wall thickness and concentricity for three insulation layers
- XLL (eXtra Long Life) X-ray tubes for long operating life with high accuracy and reliability
- Ceramic windows and NTX (Non Toxic X-ray) windows for operation throughout the service life without cleaning
- Optimized Multi-Sensor-Technology (MST) – accurate measurement even with cable vibration
- Fast centring of the crosshead and optimum quality and process control
- Measured values immediately after line start-up, with no calibration and no warm-up
- X-RAY 8000 ADVANCED: up to ten times faster acquisition of measured data immediately after line start-up for instant control
- X-RAY 8000 ADVANCED: optimization of the line start-up process
- High cable quality with maximum material and cost savings
- Dual safety system – the X-ray can only be switched on when operator safety is ensured
- Medium-voltage, high-voltage and extra-high-voltage cables
- CCV and VCV lines operating with nitrogen and/or steam
- MDCV lines (X-RAY 8700 NXT)
- Straight sector cables on CCV lines (special version)
- XLPE, EPR, EPDM, PP insulation (others on request)
We supply the equipment configured for your application. In your inquiry, please state the material processed, the required throughput and the line parameters – we will prepare a tailored quotation.
Need help choosing? Call us on +420 571 647 228 or write to info@azurr-tech.cz.
Technical data
| Application | CCV and VCV lines operating with nitrogen and/or steam |
|---|---|
| Products measured | Medium-voltage, high-voltage and extra-high-voltage cables with XLPE, EPR, EPDM or PP insulation (others on request) |
| Product diameter – CCV lines | X-RAY 8000 ADVANCED/NXT: 10–92 mm, 10–130 mm or 10–168 mm |
| Product diameter – VCV lines | X-RAY 8000 ADVANCED/NXT: 10–140 mm or 10–205 mm |
| Product diameter – X-RAY 8700 NXT | 10–94 mm, 10–145 mm or 10–180 mm (at the end of CCV, VCV, MDCV lines) |
| Accuracy | diameter ±5 µm ±0.02 % |
| Repeatability | diameter ±3.0 µm ±0.02 %; wall thickness ±7.5 µm ±0.02 % |
| Scanning speed | up to 40 mm/s |
| Radiation safety | dual safety system; radiation in the immediate vicinity of the scanner below the limits of all international regulations |
| Permissible temperature | +5 to +50 °C |
| Cooling water – consumption | approx. 70–150 l/h at max. 30 °C |
| Scanner dimensions | approx. 950 × 900 × 270 mm |
Description
SIKORA X-RAY 8000 ADVANCED/NXT is an X-ray measuring system for cable quality control on CV (continuous vulcanization) lines. These lines produce cables for demanding applications where absolute reliability is required. Measurement reliability is ensured by the combination of X-ray technology with Multi-Sensor-Technology (MST), analytical evaluation and ceramic windows.
The X-RAY 8000 NXT version combines Multi-Sensor-Technology (MST) with two high-speed scanners and ensures accurate and reliable measurement of medium-voltage, high-voltage and extra-high-voltage cables even when the cable is vibrating. Thanks to MST, each scan of the two scanners provides four measured values.
X-RAY 8000 ADVANCED with High Speed Technology (HST) is an advanced alternative to the X-RAY 8000 NXT system, adapted to the requirements of Industry 4.0. The system with 16 measuring sensors measures diameter, wall thickness and eccentricity up to ten times faster than the X-RAY 8000 NXT. Every change to the centring screw settings is recorded and displayed immediately, and four times as many measuring points as the NXT system allow measurement with almost no delay and instant control. For rapid data updates, the system automatically adapts the scan path to the cable diameter.
For measuring the wall thickness, concentricity, diameter and ovality of high-voltage cables on MDCV lines, SIKORA recommends the X-RAY 8700 NXT model, which is installed at the end of CCV, VCV and MDCV lines and provides cable parameter values measured in the cold state. It is suitable for all types of cables with solid, stranded or Milliken conductors and with single-layer, double-layer or triple-layer insulation. All systems in the series are equipped with XLL (eXtra Long Life) X-ray tubes; a special version for measuring straight sector cables on CCV lines is optionally available.
Optional equipment
More products in this category
SIKORA PLANOWAVE 6000
Online thickness measurement of plastic sheet using millimetre-wave technologySIKORA X-RAY 6000 (PRO, PURE, C-PIPE AI)
X-ray measurement of diameter, ovality, wall thickness and concentricityAll versions in the Wall thickness measurement category (4 items)