PREMOSYS OPLYTIX SPECTRA
Industrial broadband spectrometer for colour measurement and light analysis directly in the process
OPLYTIX SPECTRA is a powerful PREMOSYS broadband spectrometer for industrial applications that demand maximum spectral flexibility and the highest accuracy. It covers the range from UV to NIR, is supplied in Base and Clear variants and, thanks to its compact design and robust light guide connection, can be integrated directly into the production line.
Benefits
- Broadband spectrometer for the UV, VIS and NIR range
- Base variant: readout speed up to 4,800 Hz, 256 pixels, 360–1,700 nm
- Clear variant: high resolution, accuracy < 0.5 nm, 2,048 pixels, 190–1,100 nm
- Integration time 10.8 µs to 14 minutes
- Colour spaces CIE 1931 xy, CIE 1976 u′v′, CIE L*a*b* and XYZ
- Correlated colour temperature (CCT), dominant, peak and centroid wavelength
- Calibrated spectral data with a resolution of up to 0.5 nm
- Modbus RTU/TCP and Modbus UDP/IP for easy integration into PLC environments
- USB-C and Ethernet interfaces; powered via USB-C (5 V) or M8 connector (12–27 V)
- Anti-rotation light guide connection
- Robust surface-treated aluminium housing
- OPLYTIX SPECTRA Tool software for configuration, measurement, evaluation and data export
- Quality control – consistent product quality thanks to precise colour analysis
- Continuous real-time monitoring of production processes
- Light analysis – measurement of colour temperature and wavelengths in industrial lighting technology and manufacturing
- Inline measurement directly in the production line
- Inline monitoring of polymer melts and biotechnological processes
We supply the equipment configured for your application. In your inquiry, please state the material processed, the required throughput and the line parameters – we will prepare a tailored quotation.
Need help choosing? Call us on +420 571 647 228 or write to info@azurr-tech.cz.
Technical data
| Variants | OPLYTIX Spectra Base, OPLYTIX Spectra Clear |
|---|---|
| Wavelength range | Base: 360–1,700 nm; Clear: 190–1,100 nm |
| Number of pixels | Base: 256; Clear: 2,048 |
| Readout speed (Base) | up to 4,800 Hz |
| Accuracy (Clear) | < 0.5 nm |
| Resolution of calibrated spectral data | up to 0.5 nm |
| Integration time | 10.8 µs to 14 min |
| Interface | USB-C, Ethernet |
| Communication | Modbus RTU/TCP, Modbus UDP/IP |
| Power supply | USB-C (5 V) or M8 connector (12–27 V) |
| Colour spaces | CIE 1931 xy, CIE 1976 u′v′, CIE L*a*b*, XYZ |
| Light analysis | CCT, dominant, peak and centroid wavelength |
| Connection to the measured object | anti-rotation light guide |
| Housing | surface-treated aluminium |
| UV mini spectrometer | 190–435 nm, FPGA with 16,000 logic elements, 16-bit A/D converter 5 MS/s |
| VIS | NIR mini spectrometer | 360–830 nm, FPGA with 16,000 logic elements |
Description
OPLYTIX SPECTRA (new product 2026) is a powerful broadband spectrometer designed for demanding industrial environments. It combines compact dimensions with industrial performance and a robust surface-treated aluminium housing. It is intended for colour measurement and light analysis directly in the process, and offers exceptional spectral coverage from UV to NIR and a high measuring speed even for very fast production processes.
Two variants are available: OPLYTIX Spectra Base for high speed with a readout speed of up to 4,800 Hz (256 pixels, 360–1,700 nm) and OPLYTIX Spectra Clear with high resolution for the most precise analyses in the UV and VIS range with an accuracy of < 0.5 nm (2,048 pixels, 190–1,100 nm). Both variants have USB-C and Ethernet interfaces and an integration time from 10.8 µs to 14 minutes. On its spectroscopy pages, PREMOSYS also lists, within the OPLYTIX SPECTRA range of miniature spectrometers, a UV mini spectrometer (190–435 nm) and a VIS | NIR mini spectrometer (360–830 nm) with an integrated FPGA with 16,000 logic elements.
The spectrometer supports the CIE 1931 xy, CIE 1976 u′v′, CIE L*a*b* and XYZ colour spaces and provides the correlated colour temperature (CCT), the dominant wavelength and the peak and centroid wavelengths. Calibrated spectral data are available with a resolution of up to 0.5 nm. For easy integration into PLC environments it supports Modbus RTU/TCP and Modbus UDP/IP, and it can be powered via USB-C (5 V) or an industrial M8 connector (12–27 V). The anti-rotation light guide connection allows flexible measuring distances while maintaining stability.
The OPLYTIX SPECTRA Tool software combines device configuration, measurement, evaluation and data export in a single application; the software can be individually customized so that raw data are converted into process decisions in real time. Fields of application include quality control, continuous process monitoring, light analysis and inline monitoring of biotechnological processes and polymer melts.
Optional equipment
More products in this category
PREMOSYS DeltaLab LITE
Precise colour measurement of pellets, bulk materials, powders and inhomogeneous surfacesPREMOSYS eFLAT-S
Compact dual spectrometer for light analysis and quality control with inline integration capabilityPREMOSYS NANOS+
Dual colour and spectral sensor chip with plasmonic nanostructure filtersAll versions in the Spectrometry and colour measurement category (5 items)