PREMOSYS eFLAT-S
Compact dual spectrometer for light analysis and quality control with inline integration capability
The eFLAT-S is a very compact PREMOSYS dual spectrometer (Flexible Light Analyzer and Test System) that evaluates photoelectric measurement parameters with parallel operation of up to two spectrometers. It measures over a spectral range of 380–800 nm, communicates via Modbus UDP/IP and is used, among other things, for quality control in the approval of medical light sources.
Benefits
- Very compact dual spectrometer, parallel operation of up to two spectrometers
- Version with 1 or 2 channels (eFLAT-S-1, eFLAT-S-2)
- Spectral range 380–800 nm, sensitivity 50 to 10,000,000 lx
- Colour coordinates CIE 1931 xy and CIE 1976 u′v′, CCT and characteristic wavelengths
- Colour rendering index CRI according to CIE 13.3-95, DIN 6169, JIS Z 8726 and ANSI/IES TM-30-20
- COI index (cyanosis observation index)
- Integration time 10.8 µs to 10,000 ms with a resolution of 0.2 µs
- Fast Ethernet and Modbus UDP/IP protocol
- Ø 4 mm anti-rotation light guide connection
- 3.5″ capacitive touch display
- Experience with inline integration into production lines
- Quality control in the approval of medical light sources
- Measurement of lamps for cyanosis detection
- Measurement of white and monochromatic LEDs
- Analysis of substances by evaluating photoelectric measurement parameters
- Inline integration into production lines
We supply the equipment configured for your application. In your inquiry, please state the material processed, the required throughput and the line parameters – we will prepare a tailored quotation.
Need help choosing? Call us on +420 571 647 228 or write to info@azurr-tech.cz.
Technical data
| Number of channels | 1 or 2 (eFLAT-S-1, eFLAT-S-2) |
|---|---|
| Spectral range | 380–800 nm |
| Output quantities | XYZ, CIE 1931 xy, CIE 1976 u′v′, CCT, λdom, λPeak, λCentroid, Δλ, λCenter, CRI, COI |
| Integration time | 10.8 µs to 10,000 ms, resolution 0.2 µs |
| Accuracy – white LED (after calibration) | colour coordinates x, y ± 0.0025; relative intensity ± 5 %; CCT resolution 1 K |
| Accuracy – monochromatic LED (after calibration) | λdom < ± 2 nm; λdom resolution 1 nm |
| Sensitivity | 50 to 10,000,000 lx |
| Measuring time (incl. data transfer) | 8 ms + longest integration time used |
| Interface | Fast Ethernet RJ45, Modbus UDP/IP |
| Connection to the measured object | light guide with Ø 4.00 mm anti-rotation connector |
| Display | 3.5″ IPS, 320 × 480 px, capacitive touch, 400 cd/m² |
| Power supply | 12–27 V DC; typ. 200 mA (eFLAT-S-1) / 300 mA (eFLAT-S-2) at 24 V |
| Protection | internal electronic, self-resetting |
| Housing material | surface-treated aluminium |
| Ingress protection | IP20 |
| Operating temperature | 10–50 °C |
| Operating humidity | 35–85 % relative humidity |
| Storage temperature | -10 to 60 °C |
Downloads
- Datasheet (EN) PDF
Description
According to the manufacturer, the eFLAT-S is a globally unique, very compact dual spectrometer. The system, based on the latest technology, guarantees very high process reliability in the analysis of substances by evaluating photoelectric measurement parameters with parallel operation of up to two spectrometers. It is supplied in single-channel (eFLAT-S-1) and dual-channel (eFLAT-S-2) versions.
The instrument operates over a spectral range of 380–800 nm and, depending on the installed firmware and the activated software options, provides XYZ, CIE 1931 xy and CIE 1976 u′v′ coordinates, the correlated colour temperature (CCT), the dominant, peak, centroid and centre wavelengths, Δλ, the colour rendering index CRI (according to CIE 13.3-95, DIN 6169, JIS Z 8726 and ANSI/IES TM-30-20) and the COI index (cyanosis observation index). The sensitivity covers the range of 50 to 10,000,000 lx.
The integration time is adjustable from 10.8 µs to 10,000 ms with a resolution of 0.2 µs; the measuring time including data transfer is 8 ms + the longest integration time used, regardless of the number of channels used. Communication takes place via Fast Ethernet (RJ45) using the Modbus UDP/IP protocol, and light guides are connected with a Ø 4 mm anti-rotation connector. The instrument has a 3.5″ capacitive touch display.
With the eFLAT-S, PREMOSYS has experience with inline integration into production lines. The spectrometer is used for quality control in the approval of medical light sources, for example lamps for cyanosis detection.
Optional equipment
More products in this category
PREMOSYS C.E.B.R.A.
Broadband laboratory spectrometer 250–1,100 nm for photometric, spectral and kinetic measurementsPREMOSYS NANOS+
Dual colour and spectral sensor chip with plasmonic nanostructure filtersPREMOSYS OPLYTIX SPECTRA
Industrial broadband spectrometer for colour measurement and light analysis directly in the processAll versions in the Spectrometry and colour measurement category (5 items)