TPT4636-10M-6/18
Order code: 04636000135 · Dynisco- Accuracy: ± 0.50% FSO
- Process connection: 1/2-20UNF
- Pressure range: 10,000 psi
TPT4196-10M-6/18 (order code 04196300135) – melt pressure sensor by Dynisco, PT series. Main parameters: accuracy ± 0.50% FSO, process connection 1/2-20UNF, pressure range 10,000 psi, rigid stem length 15 cm, flexible capillary length 46 cm.
The PT4196 is a sensor with an accuracy of ±0.5%, ideal for applications in the food and pharmaceutical industries that require easy installation, repeatability and reliability. An alternative food-grade oil fill meets USDA and FDA requirements. The PT4196 provides a standard 0–10 Vdc signal designed to work with DCS and PLC systems. Optional thermocouple or RTD configurations are also available, providing simultaneous melt temperature and pressure measurement at a single point. The PT4196 has a 1/2-20UNF thread for easy installation in standard mounting holes.
We will send you the price, delivery time and any available variants in our quotation.
Need help choosing? Call us on +420 571 647 228 or write to info@azurr-tech.cz.
| Accuracy | ± 0.50% FSO |
|---|---|
| Process connection | 1/2-20UNF |
| Pressure range | 10,000 psi |
| Rigid stem length | 15 cm |
| Flexible capillary length | 46 cm |
| Integrated temperature sensor | Type J thermocouple |
| Output signal | 0-10 VDC |
| Transducer excitation | 16 - 36 Vdc |
Our pressure transducers offer an efficient, accurate and durable solution for reliable and safe pressure measurement. They are used in many industrial sectors, where they monitor and measure melt pressure and ensure optimum operation of production processes. Thanks to their resistance to the high temperatures and pressures typical of these applications, they are a suitable choice for a wide range of uses. When selecting a transducer, it is important to consider the specific requirements of your application, such as the temperature range, the pressure range and the materials the transducer will come into contact with. Choosing the right transducer guarantees reliable, accurate results and a long, trouble-free service life. Installing the transducer in the mounting hole of the production line is straightforward.

Pressure transducers with a rigid stem are easy to install in the mounting hole of the production line thanks to their simple, robust design, which is suitable for applications where the transducer is not exposed to radiant heat from the line and the electronics are not exposed to extreme temperatures. We do not recommend installing these transducers vertically above the line (12 o'clock position), as radiant heat may shorten the service life of the transducer electronics. In that case we recommend a transducer design with a flexible capillary, which allows the electronics to be moved away from the radiant heat and ensures a long transducer life. The main advantages of this transducer type include resistance to shock and vibration, which enables it to withstand mechanical stress, extending its service life and reducing maintenance requirements. It also offers high accuracy, ensured by high-quality materials and advanced measurement technology, which is essential for efficient process control.

Pressure transducers with a flexible capillary are a professional solution for applications with limited space or exposure to radiant heat from the heating elements of production lines. Thanks to the well-thought-out extended design, the transducer electronics are located away from the source of radiant heat, reducing the risk of damage.
The flexible capillary is designed to resist damage and allow a high degree of bending, which makes installing and handling the transducer easier. The transducer head must be properly secured in the bracket supplied with the transducer. For optimum performance, we recommend mounting the bracket on a part of the machine that is free from unwanted vibration or shocks that could adversely affect the transducer.
The rigid stem length and the flexible capillary length can be adapted to individual needs, as can other optional components. This ensures maximum flexibility when integrating the transducer into a wide range of industrial applications.

Combined pressure transducers with a flexible capillary are a professional solution for applications with limited space or exposure to radiant heat from the heating elements of production lines. Thanks to the well-thought-out extended design, the transducer electronics are located away from the source of radiant heat, reducing the risk of damage.
These transducers are also fitted with a temperature sensor, and the customer can choose the sensor type: a type J or K thermocouple or an RTD (Sensor RTD). With a compatible temperature sensor selected, the customer also obtains the melt temperature from a single process connection, which increases the efficiency and accuracy of measurement.
The flexible capillary is designed to resist damage and allow a high degree of bending, which makes installing and handling the transducer easier. The transducer head must be properly secured in the bracket supplied with the transducer. For optimum performance, we recommend mounting the bracket on a part of the machine that is free from unwanted vibration or shocks that could adversely affect the transducer.
The rigid stem length and the flexible capillary length can be adapted to individual needs, as can other optional components. This ensures maximum flexibility when integrating the transducer into a wide range of industrial applications.