LMI5500, LMFI55-2NENNNN
Order code: LMFI55-2NENNNN · Dynisco- Digital encoder: Included
- Standard temperature control: Standard ISO 1133 / ASTM1238
- Automatic cutting system: Not equipped
LMI5500, LMFI55-2NENNCN (order code LMFI55-2NENNCN) – melt flow indexer by Dynisco, LMI 5500 series. Main parameters: digital encoder Included, standard temperature control Standard ISO 1133 / ASTM1238, automatic cutting system Included, power supply 220-240 Vac 50/60Hz, barrel type Standard tool steel.
This LMFI5500 series melt flow indexer allows most rheological parameters of thermoplastics to be measured, including the IV of PET. The LMFI 5500 series is among the most accurate instruments of its kind in the world. Intuitive controls make operation easy; an expert mode for experienced operators significantly shortens the entire measurement process, and sophisticated functions and technologies ensure the highest possible measurement accuracy. With gravity correction and two-zone heating, it not only meets but exceeds the requirements of the latest ISO1133-2 standard.
This model is ideal for quality control in laboratories, institutes or universities where accuracy really matters. Try the LMFI 5500 and get a reliable, accurate instrument that will help you improve the quality of your products.
We will send you the price, delivery time and any available variants in our quotation.
Need help choosing? Call us on +420 571 647 228 or write to info@azurr-tech.cz.
| Digital encoder | Included |
|---|---|
| Standard temperature control | Standard ISO 1133 / ASTM1238 |
| Automatic cutting system | Included |
| Power supply | 220-240 Vac 50/60Hz |
| Barrel type | Standard tool steel |

It was developed for processors to obtain detailed analyses easily, and it makes it possible to correlate laboratory and production rheology instruments for all facilities worldwide on a single cloud dashboard and to view any instrument in real time, 24 hours a day, 7 days a week, 365 days a year.
The digital encoder allows highly accurate measurement of piston displacement in Method A/B and B tests.
The automatic cutter blade rotates at defined times in Method A and Method A/B testing and ensures stable, uniform extrudate cuts even at high flow rates. It also cuts the sample at the end of the preheat time, regardless of the method. It results in more consistent sample cutting than manual cutting.

| Melt flow index: | MFR - Melt Flow Rate [g/10min] |
|---|---|
| Melt flow index: | MVR - Melt Volume Rate [ccm/10min] |
| Melt density: | MD - Melt Density [g/ccm] |
| Intrinsic viscosity (PET): | IV - Intrinsic viscosity [dl/g] |
| Shear viscosity: | Shear Viscosity [Pa.s] |
| Shear rate: | Shear Rate [1/s] |
| Complies with standards: | ISO1133-1, ISO1133-2, ASTM D1238 & D3364, BS2782, DIN 53735, JIS K7210 |
|---|---|
| Operating temperature: | Max. 400°C |
| Temperature control accuracy: | ±0.10°C |
| Timer accuracy: | 0.001 s |
| Digital encoder accuracy: | ±0.025mm |
| Display: | 7" touch screen; viewing angle 130° ; resolution 800 x 480 pixels |
| Weights: | Aluminium, stainless or coated steel, 0.325 to 31.6 kg |
| Communication: |
- 4x USB port |
| Gravity correction: | YES |
| Expert mode: | YES |
| Selectable colour scheme: | YES |
| Dynisco Cloud: | YES |
| Dynisco Service Care: | YES |
| Adjustable PID control: | YES |
| Overall dimensions, base model: | 13W x 21D x 20H in. (33W x 53D x 51H cm) |
|---|---|
| Weight, base model: | 47 lbs. (21.3 Kg) |
| Shipping weight, base model with weights: | 180 lbs. (81.8 Kg) |
| System voltage: | 100-120Vac 50/60Hz or 220-240Vac 50/60Hz, 500VA, + 5% , single phase |
| Power: | max. 500 W, typically 100 W at setpoint |